CONTEC CMS7000 PLUS 12.1inch LCD Touch Screen ICU Patient Monitor
Introduction
This Patient Monitoring Device can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving.
Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1-ECG Heart rate(HR): ECG waveform; Arrhythmia and ST-segment analysis.
2-RESP Respiration rate(RR): Respiration waveform
3-SpO2 Oxygen saturation(SpO2): Plethysmogram(PLETH) waveform; Pulse rate(PR); Bar graph.
4-NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5-TEMP T1, T2, TD
This Patient Monitoring Device has abundant functions, such as touch-screen operation, audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.
Features
1)12.1" TFT color LCD, multi-language interface (English, Chinese, Russian, Kazakhstan, Czech, Slovak).
2)Touch screen operation, which improves the working efficiency for medical staff.
3)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
4)all-round monitor for adult, pediatric and neonate.
5)With the standard interface, big character interface and view bed, convenient to observe.
6)Waveform, parameter color and location can be set optionally.
7)Maximum 8-channel waveform synchronous display
8)Display a 7-lead ECG waveform on one screen.
9)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak flling.
10)NIBP measurement mode: Manual/AUTO/Continuous, storage for 4800-group NIBP data.
11)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
12)Drug concentration calculation and titration table functions.
13)Connect to Central Monitoring System by 3G, Wi-Fi, or wired mode.
14)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
15)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).
Performance
▲ECG
Lead mode |
3-lead or 5-lead |
Lead selection |
I, II, III, aVR, aVL, aVF, V |
Waveform |
5-lead, dual-channel |
3-lead, single-channel | |
Gain |
2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV |
Scan speed |
12.5mm/s, 25 mm/s, 50 mm/s |
HR |
|
Measurement and alarm range |
15~350 bpm |
Accuracy |
±1 % or ±1 bpm, whichever is greater |
Alarm accuracy |
± 2 bpm |
Resolution |
1 bpm |
ST-segment monitoring |
|
Measurement and alarm range |
-2 mV ~ +2 mV |
Accuracy |
-0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater |
Other range |
unspecified |
Arrhythmia analysis |
ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC |
Pacemaker |
yes |
▲RESP
Method |
R-F(RA-LL) Impedance |
Respiration rate |
|
Measurement and alarm range |
0~150 rpm |
Resolution |
1 rpm |
Measurement accuracy |
±2 rpm |
Alarm accuracy |
±3 rpm |
Apnea alarm |
10~40s |
Scan speed |
6.25 mm/s, 12.5 mm/s, 25 mm/s |
▲NIBP
Method |
Oscillometry |
Mode |
Manual/AUTO/Continuous |
Measurement interval in AUTO mode |
1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes |
Measurement period in Continuous mode |
5 minutes |
Measurement and alarm range |
10 ~ 270 mmHg |
Resolution |
1 mmHg |
Cuff pressure accuracy |
±3 mmHg |
Measurement accuracy |
|
Maximal mean deviation |
±5 mmHg |
Maximal standard deviation |
8 mmHg |
Over-pressure protection |
|
Adult mode |
297±3 mmHg |
Pediatric mode |
240±3 mmHg |
Neonatal mode |
147±3 mmHg |
▲SpO2
Measurement and alarm range |
0 ~ 100% |
Resolution |
1% |
Measurement accuracy |
70%~100%: ±2%; |
0%~69% |
unspecified |
▲PR
Measurement and alarm range |
30 ~ 250 bpm |
Measurement accuracy |
±2 bpm or ±2%, whichever is greater |
▲TEMP
Channel |
dual-channel |
Measurement and alarm range |
0 ~ 50℃ |
Resolution |
0.1 ℃ |
Accuracy |
±0.1 ℃ |
▲EtCO2
Method |
Sidestream or Mainstream |
Measuring Range |
0~150mmHg |
Resolution |
0~69 mmHg, 0.1 mmHg |
70~150 mmHg, 0.25 mmHg | |
Accuracy | |
0~40 mm Hg ±2 mm Hg | |
41~70 mm Hg ±5% | |
71~100 mm Hg ±8% | |
101~150 mm Hg ±10% | |
AwRR Range |
2~150 rpm |
AwRR Accuracy |
±1BPM |
Apnea Alarm |
Yes |
▲IBP
Channel |
dual-channel |
Label |
ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
Measuring and Alarm Range |
-10~300 mmHg |
Resolution 1 mmHg |
|
Accuracy |
±2% or 1mmHg, whichever is greater |
▲Power supply |
220 V, 50 Hz |
▲Safety classification |
Class I, type CF defibrillation-proof applied part |
Accessories
1)Adult fingertip SpO2 probe (5-pin)
2)Adult NIBP cuff
3)NIBP extension tube
4)ECG lead cable
5)ECG electrode
6)Temperature probe
7)Power cord
8)User Manual
Physical characteristic
Dimension: 319 mm(L) × 161 mm(W) × 269 mm(H)
Weight: 3.6 Kg